Pre-compliance: find EMC problems while they are still cheap.
The most expensive EMC failure is the one found at the formal test, a week before launch. A pre-compliance bench moves that discovery to the prototype.
A typical set-up
- A receiver or spectrum analyser with EMI detectors, and a line impedance stabilization network (LISN)
- Near-field probes for finding where on the board the noise comes from
- A small shielded space, a GTEM cell or a compact chamber for radiated checks
- ESD and burst generators for the most common immunity failures
What it tells you
Pre-compliance results are comparisons, not certificates: they show whether a design change helped, and how much margin you have against the limit. The formal test still happens in a full-compliance set-up.
Go deeper on testups.com
Planning an EMC lab or an upgrade?
TESTUPS designs, sources and supplies EMC chambers, test systems and components, and supports installation, site validation and accreditation preparation.